Home Forums Printing Discussions Roland Printers Roland Service Menu

  • Andre Woodcock

    Member
    19 April 2008 at 05:45

    Mike I got the following from a Roland tech I’ve tried it and it works

    This is depend on the firmware version so please try below two method,

    Please switch on the machine from the back side and then

    1. Please press UP.LEFT,RIGHT,DOWN,LEFT,DOWN,RIGHT arrow keys and then immediately by keep pressing the LEFT,DOWN,RIGHT arrow keys (please press and hold these three keys) power on the machine from the panel.

    2. Please press DOWN,RIGHT,LEFT,UP,RIGHT,DOWN,LEFT arrow keys and then immediately by keep pressing the LEFT,DOWN,RIGHT arrow keys (please press and hold these three keys) power on the machine from the panel.

    Andre

  • Michael Almand

    Member
    20 April 2008 at 16:01

    Thank you very much Andre I will try that.

    Mike

  • Kreatorbg

    Member
    26 June 2008 at 15:55

    Michael, Andre is right. It depends on the firmware. I "discover" it every time when I stand in front of a new machine. On the VP series, the most that works for me is: DOWN RIGHT, LEFT UP, and after this RIGHT DOWN LEFT POWER

    Regards
    Ivan